This pipe feature class represents current wastewater information of the mainline sewer in the City of Los Angeles. The Mapping and Land Records Division of the Bureau of Engineering, Department of Public Works provides the most rigorous geographic information of the storm drain system using a geometric network model, to ensure that its storm drains reflect current ground conditions. The conduits and inlets represent the storm drain infrastructure in the City of Los Angeles. Storm drain information is available on NavigateLA, a website hosted by the Bureau of Engineering, Department of Public Works.Associated information about the wastewater Pipe is entered into attributes. Principal attributes include:PIPE_SUBTYPE: pipe subtype is the principal field that describes various types of lines as either Airline, Force Main, Gravity, Siphon, or Special Lateral.For a complete list of attribute values, please refer to (TBA Wastewater data dictionary). Wastewater pipe lines layer was created in geographical information systems (GIS) software to display the location of sewer pipes. The pipe lines layer is a feature class in the LACityWastewaterData.gdb Geodatabase dataset. The layer consists of spatial data as a line feature class and attribute data for the features. The lines are entered manually based on wastewater sewer maps and BOE standard plans, and information about the lines is entered into attributes. The pipe lines are the main sewers constructed within the public right-of-way in the City of Los Angeles. The ends of line segments, of the pipe lines data, are coincident with the wastewater connectivity nodes, cleanout nodes, non-structures, and physical structures points data. Refer to those layers for more information. The wastewater pipe lines are inherited from a sewer spatial database originally created by the City's Wastewater program. The database was known as SIMMS, Sewer Inventory and Maintenance Management System. For the historical information of the wastewater pipe lines layer, refer to the metadata nested under the sections Data Quality Information, Lineage, Process Step section. Pipe information should only be added to the Wastewater Pipes layer if documentation exists, such as a wastewater map approved by the City Engineer. Sewers plans and specifications proposed under private development are reviewed and approved by Bureau of Engineering. The Department of Public Works, Bureau of Engineering's, Brown Book (current as of 2010) outlines standard specifications for public works construction. For more information on sewer materials and structures, look at the Bureau of Engineering Manual, Part F, Sewer Design, F 400 Sewer Materials and Structures section, and a copy can be viewed at http://eng.lacity.org/techdocs/sewer-ma/f400.pdf.List of Fields:STREET: This is the street name and street suffix on which the pipe is located.PIPE_LABEL: This attribute identifies the arc segment between two nodes, which represents the pipe segment. There could be any number of pipes between the same two maintenance holes and at least one. If there is more than one pipe between the same two maintenance holes, then a value other than 'A' is assigned to each pipe, such as the value 'B', 'C', and so on consecutively. Also, when a new pipe is constructed, some old pipes are not removed from the ground and the new pipe is added around the existing pipe. In this case, if the original pipe was assigned an 'A', the new pipe is assigned a 'B'.C_UP_INV: This is the calculated pipe upstream invert elevation value.PIPE_MAT: The value signifies the various materials that define LA City's sewer system. Values:     • TCP - Terra Cotta pipe.     • CMP - Corrugated metal pipe.     • RCP - Reinforced concrete pipe. Used for sewers larger than 42inch, with exceptions.     • PCT - Polymer concrete pipe.     • CON - Concrete or cement.     • DIP - Ductile iron pipe.     • ABS - Acrylonitrile butadiene styrene.     • STL - Steel.     • UNK - Unknown.     • ACP - Asbestos cement pipe.     • RCL - Reinforced concrete pipe lined.     • OTH - Other or unknown.     • VCP - Vitrified clay pipe.     • TRS - Truss pipe.     • CIP - Cast iron pipe.     • PVC - Polyvinyl chloride.     • BRK - Brick.     • RCPL - Lined Reinforced concrete pipe. Used for sewers larger than 42inch, with exceptions.     • B/C - Concrete brick pipe.     • FRP - Centrifugally cast fiberglass reinforced plastic mortar pipe.DN_INV: This is the downstream invert elevation value.PIPE_WIDTH: This value is the pipe dimension for shapes other than round.C_SLOPE: This is the calculated slope.ENABLED: Internal feature number.DN_STRUCT: This attribute identifies a number at one of two end points of the line segment that represents a sewer pipe. A sewer pipe line has a value for the UP_STRUCT and DN_STRUCT fields. This point is the downstream structure that may be a maintenance hole, pump station, junction, etc. Each of these structures is assigned an identifying number that corresponds to a Sewer Wye data record. The 8 digit value is based on an S-Map index map using a standardized numbering scheme. The S-Map is divided into 16 grids, each numbered sequentially from west to east and north to south. The first three digits represent the S-Map number, the following two digits represent the grid number, and the last three digits represent the structure number within the grid. This field also relates to the (name of table or layer) node attribute table.PIPE_SIZE: This value is the inside pipe diameter in inches.MON_INST: This is the month of the pipe installation.PIPE_ID: The value is a combination of the values in the UP_STRUCT, DN_STRUCT, and PIPE_LABEL fields. This is the 17 digit identifier of each pipe segment and is a key attribute of the pipe line data layer. This field named PIPE_ID relates to the field in the Annotation Pipe feature class and to the field in the Wye line feature class data layers.REMARKS: This attribute contains additional comments regarding the pipe line segment.DN_STA_PLS: This is the tens value of the downstream stationing.EASEMENT: This value denotes whether or not the pipe is within an easement.DN_STA_100: This is the hundreds value of the downstream stationing.PIPE_SHAPE: The value signifies the shape of the pipe cross section. Values:     • SE - Semi-Elliptical.     • O1 - Semi-Elliptical.     • UNK - Unknown.     • BM - Burns and McDonald.     • S2 - Semi-Elliptical.     • EL - Elliptical.     • O2 - Semi-Elliptical.     • CIR - Circular.     • Box - Box (Rectangular).PIPE_STATUS: This attribute contains the pipe status. Values:     • U - Unknown.     • P - Proposed.     • T - Abandoned.     • F - As Built.     • S - Siphon.     • L - Lateral.     • A - As Bid.     • N - Non-City.     • R - Airline.ENG_DIST: LA City Engineering District. The boundaries are displayed in the Engineering Districts index map. Values:     • O - Out LA.     • V - Valley Engineering District.     • W - West LA Engineering District.     • H - Harbor Engineering District.     • C - Central Engineering District.C_PIPE_LEN: This is the calculated pipe length.OWNER: This value is the agency or municipality that constructed the pipe. Values:     • PVT - Private.     • CTY - City of LA.     • FED - Federal Facilities.     • COSA - LA County Sanitation.     • OUTLA - Adjoining cities.CRTN_DT: Creation date of the line feature.TRTMNT_LOC: This value is the treatment plant used to treat the pipe wastewater.PCT_ENTRY2: This is the flag determining if the second slope value, in SLOPE2 field, was entered in percent as opposed to a decimal. Values:     • Y - The value is expressed as a percent.     • N - The value is not expressed as a percent.UP_STA_100: This is the hundreds value of the upstream stationing.DN_MH: The value is the ID of the structure. This point is the structure that may be a maintenance hole, pump station, junction, etc. The field name DN_MH signifies the structure is the point at the downstream end of the pipe line segment. The field DN_MH is a key attribute to relate the pipe lines feature class to the STRUCTURE_ID field in the physical structures feature class.SAN_PIPE_IDUSER_ID: The name of the user carrying out the edits of the pipe data.WYE_MAT: This is the pipe material as shown on the wye card.WYE_DIAM: This is the pipe diameter as shown on the wye card.SLOPE2: This is the second slope value used for pipe segments with a vertical curve.EST_YR_LEV: This value is the year installed level.EST_MATL: This is the flag determining if the pipe material was estimated.LINER_DATE: This value is the year that the pipe was re-lined.LAST_UPDATE: Date of last update of the line feature.SHAPE: Feature geometry.EST_YEAR: This is the flag indicating if the year if installation was estimated.EST_UPINV: This is the flag determining if the pipe upstream elevation value was estimated.WYE_UPDATE: This value indicates whether the wye card was updated.PCT_ENTRY: This is the flag determining if the slope was entered in percent as opposed to a decimal. Values:     • N - The value is not expressed as a percent.     • Y - The value is expressed as a percent.PROF: This is the profile drawing number.PLAN1: This is the improvement plan drawing number.PLAN2: This is the supplementary improvement plan drawing number.EST_DNINV: This is the flag determining if the pipe downstream elevation value was estimated.UP_STRUCT: This attribute identifies a number at one of two end points of the line segment that represents a sewer pipe. A sewer pipe line has a value for the UP_STRUCT and DN_STRUCT fields. This point is the upstream structure that may be a maintenance hole, pump station, junction, etc. Each of these structures is assigned an identifying number that corresponds to a Sewer Wye data record. The 8 digit value is based on an S-Map index map using a standardized numbering scheme. The S-Map is divided into 16 grids, each numbered sequentially from west to east and north to south. The first three digits represent the S-Map number, the following two digits represent the grid number, and the last three digits represent the structure number within the grid. This field also relates to the (name of table or layer) node attribute table.SYSTEM: This attribute identifies the major sewer and sewer outfall system the pipe is associated with. Values:     • VRS - Venice relief sewer.     • GBIS - Glendale Burbank interceptor sewer.     • WLAIS - West Los Angeles interceptor sewer.     • NOS - North outfall sewer.     • LCIS - La Cienega interceptor sewer.     • WRS - Westwood relief sewer.     • VOS - Venice outfall sewer.     • RRS - Robertson relief sewer.     • NEIS - North East interceptor sewer.     • NCOS - North Central outfall sewer.     • MAZE - Area of many sewer junctions and interconnections.     • WHIS - Wilshire-Hollywood interceptor sewer.     • CIS - Coastal interceptor sewer.     • NORS - North outfall replacement sewer.     • LCSFVRS - La Cienega San Fernando Valley relief sewer.     • ECIS - East Central interceptor sewer.     • COS - Central outfall sewer.     • VORS - Valley outfall relief sewer.     • AVORS - Additional Valley outfall relief sewer.     • EVRS - East Valley relief sewer.     • EVIS - East Valley interceptor sewer.V_CURVE: This is the flag for pipe segments with a vertical curve.UP_MH: The value is the ID of the structure. This point is the structure that may be a maintenance hole, pump station, junction, etc. The field name UP_MH signifies the structure is the point at the upstream end of the pipe line segment. The field UP_MH is a key attribute to relate the pipe lines feature class to the STRUCTURE_ID field in the physical structures feature class.OBJECTID: Internal feature number.CAPACITY: This value is a calculated pipe capacity based on its slope and shape.VDATUM: This is the year of the standard plan, which contains the information the user enters into pipe data.WYE_LENG: This is the pipe length as shown on the wye card.REHAB: This attribute indicates if the pipe has been rehabilitated.GRV_FM: The value describes the type of flow that the pipe is handling. Values:     • GR - Gravity flow.     • SI - Siphon condition.     • FM - Force main.     • AL - Air line.     • AV - Air Vent.HR_VER: This value flags the pipe line segment as either horizontal, vertical, or both. Values:     • V - Vertical curve.     • B - Both horizontal and vertical curves.     • H - Horizontal curve.PIPE_SUBTYPE: This attribute is the pipe subtype.SLOPE_PCT: This value is the percentage of slope of the pipe shown as a decimal value.YEAR_INST: This is the year of pipe installation.COMMENTS: This attribute contains comments regarding the pipe status.LINER: The value describes the basic material used to rehab a pipe. Values:     • S - Steel liner.     • L - Plastic liner.     • T - Tile liner.WYEMAP: This is the wye card number reference.UP_INV: This is the upstream invert elevation value.UP_STA_PLS: This is the tens value of the upstream stationing.BASIN: This attribute is the basin number.CLASS: This attribute is the sewer class the pipe belongs to. Values:     • 3 - Secondary Sewer.     • 2 - Primary Sewer.     • 0 - Unknown.     • 1 - Major Outfall or Interceptor.WYE_CON: This is the number of wye connections served by pipe segment. There are up to 51 wye connections in the current data.ASSETID: User-defined unique feature number that is automatically generated.BLOCK: This is the block number on which the pipe is located.SERVICEID: User-defined unique feature number that is automatically generated.PIPE_LENG: This is the length of the pipe segment.C_DN_INV: This is the calculated pipe downstream invert elevation value.NO_LAT: This is the number of laterals served by pipe segment. There are up to 50 laterals in the current data.SHAPE_Length: Length of feature in internal units.

Dataset Attributes

  • OBJECTID
    Number
  • Shape
    Number
  • Enabled
    Number
    {"value"=>"True", "count"=>2163, "code"=>1} ()
  • ASSETID
    Number
    152197 to 1847824
  • SERVICEID
    Text
  • PIPE_ID
    Text
    {"value"=>"4681104646811216A", "count"=>1} (), {"value"=>"5350215353502138A", "count"=>1} (), {"value"=>"5350213853502154A", "count"=>1} (), {"value"=>"5350211653502153A", "count"=>1} (), {"value"=>"5350211553502116A", "count"=>1} (), {"value"=>"5350214353502147A", "count"=>1} (), {"value"=>"5350214753502115A", "count"=>1} (), {"value"=>"5211417552114090A", "count"=>1} (), {"value"=>"5350211853502136A", "count"=>1} (), {"value"=>"5350213753502118A", "count"=>1} ()
  • PIPE_CLASS
    Number
    {"value"=>"Major Outfall or Interceptor", "count"=>2163, "code"=>1} ()
  • PIPE_SUBTYPE
    Number
    1 to 4
  • UP_STRUCT
    Number
    35716184 to 62404001
  • DN_STRUCT
    Number
    35716184 to 62408001
  • PIPE_LABEL
    Text
    {"value"=>"A", "count"=>2138, "code"=>"A"} (), {"value"=>"B", "count"=>19, "code"=>"B"} (), {"value"=>"D", "count"=>4, "code"=>"D"} (), {"value"=>"C", "count"=>2, "code"=>"C"} ()
  • REMARKS
    Text
    {"value"=>" ", "count"=>1563} (), {"value"=>"BONDED", "count"=>12} (), {"value"=>"pipe_id", "count"=>11} (), {"value"=>"INTERCEPTOR", "count"=>9} (), {"value"=>"NCPIPE", "count"=>4} (), {"value"=>"INTERCEPTING SEWER", "count"=>3} (), {"value"=>"REFILL SEWER NOT IN USE", "count"=>2} (), {"value"=>"BONDED SEWER", "count"=>1} ()
  • ENG_DIST
    Text
    {"value"=>"Central", "count"=>836, "code"=>"C"} (), {"value"=>"Valley", "count"=>719, "code"=>"V"} (), {"value"=>"West LA", "count"=>508, "code"=>"W"} (), {"value"=>"Out LA", "count"=>86, "code"=>"O"} (), {"value"=>"Harbor", "count"=>14, "code"=>"H"} ()
  • BASIN
    Text
    {"value"=>"W01", "count"=>215} (), {"value"=>"E15", "count"=>185} (), {"value"=>"A02", "count"=>176} (), {"value"=>"U01", "count"=>115} (), {"value"=>"E01", "count"=>111} (), {"value"=>"P01", "count"=>106} (), {"value"=>"P21", "count"=>96} (), {"value"=>"S03", "count"=>81} (), {"value"=>"W18", "count"=>72} (), {"value"=>"C10", "count"=>70} ()
  • UP_INV
    Number
    -69 to 922.66
  • DN_INV
    Number
    -69 to 2648
  • PIPE_LENG
    Number
    -2464.7 to 14171
  • SLOPE_PCT
    Number
    -0.9984 to 0.7922
  • PIPE_SIZE
    Number
    6 to 150
  • PIPE_WIDTH
    Number
    0 to 156
  • PIPE_MAT
    Text
    {"value"=>"RCP", "count"=>1091} (), {"value"=>"VCP", "count"=>408} (), {"value"=>"CON", "count"=>355} (), {"value"=>"B/C", "count"=>227} (), {"value"=>"GFR", "count"=>35} (), {"value"=>"DIP", "count"=>24} (), {"value"=>"HDPE", "count"=>9} (), {"value"=>"CIP", "count"=>9} (), {"value"=>"STL", "count"=>4} (), {"value"=>"CIPC", "count"=>1} ()
  • PIPE_SHAPE
    Text
    {"value"=>"Circular", "count"=>1232, "code"=>"CIR"} (), {"value"=>"Semi Elliptical", "count"=>621, "code"=>"SE"} (), {"value"=>"CR", "count"=>162, "code"=>"CR"} (), {"value"=>"Burns & McDonald", "count"=>102, "code"=>"BM"} (), {"value"=>"Box", "count"=>41, "code"=>"BOX"} (), {"value"=>"BX", "count"=>4, "code"=>"BX"} (), {"value"=>"EL", "count"=>1, "code"=>"EL"} ()
  • REHAB
    Text
    {"value"=>"No", "count"=>1809, "code"=>"N"} (), {"value"=>"Yes", "count"=>354, "code"=>"Y"} ()
  • STREET
    Text
    {"value"=>"VICTORY BLVD", "count"=>107} (), {"value"=>"VANOWEN ST", "count"=>78} (), {"value"=>"RODEO RD", "count"=>63} (), {"value"=>"PACIFIC COAST HWY", "count"=>53} (), {"value"=>"WOODMAN AVE", "count"=>49} (), {"value"=>"JEFFERSON BLVD", "count"=>49} (), {"value"=>"RIVERSIDE DR", "count"=>43} (), {"value"=>"VISTA DEL MAR", "count"=>42} (), {"value"=>"BURBANK BLVD", "count"=>37} (), {"value"=>"VALLEY SPRING LN", "count"=>32} ()
  • BLOCK
    Text
    {"value"=>" ", "count"=>323} (), {"value"=>"5900", "count"=>44} (), {"value"=>"4500", "count"=>40} (), {"value"=>"6000", "count"=>31} (), {"value"=>"4000", "count"=>26} (), {"value"=>"400", "count"=>25} (), {"value"=>"5700", "count"=>25} (), {"value"=>"300", "count"=>24} (), {"value"=>"2000", "count"=>24} (), {"value"=>"4100", "count"=>22} ()
  • LINER
    Text
    {"value"=>"T", "count"=>153} (), {"value"=>"P5", "count"=>108} (), {"value"=>"F3", "count"=>98} (), {"value"=>"S", "count"=>42} (), {"value"=>"I1", "count"=>38} (), {"value"=>"I2", "count"=>28} (), {"value"=>"C1", "count"=>26} (), {"value"=>"L", "count"=>23} (), {"value"=>"P4", "count"=>3} ()
  • C_SLOPE
    Text
    {"value"=>"NO", "count"=>2131, "code"=>"N"} (), {"value"=>"YES", "count"=>30, "code"=>"Y"} (), {"value"=>" ", "count"=>2, "code"=>" "} ()
  • C_UP_INV
    Text
    {"value"=>"N", "count"=>621} (), {"value"=>"F", "count"=>598} (), {"value"=>" ", "count"=>565} (), {"value"=>"Y", "count"=>11} (), {"value"=>"T", "count"=>5} ()
  • C_DN_INV
    Text
    {"value"=>"N", "count"=>1014} (), {"value"=>"F", "count"=>597} (), {"value"=>" ", "count"=>307} (), {"value"=>"Y", "count"=>29} (), {"value"=>"T", "count"=>6} ()
  • C_PIPE_LEN
    Text
    {"value"=>"N", "count"=>1034} (), {"value"=>"F", "count"=>587} (), {"value"=>" ", "count"=>307} (), {"value"=>"T", "count"=>16} (), {"value"=>"Y", "count"=>9} ()
  • UP_STA_100
    Number
    0 to 633
  • UP_STA_PLS
    Number
    -82 to 99.91
  • DN_STA_100
    Number
  • DN_STA_PLS
    Number
  • YEAR_INST
    Text
  • NO_LAT
    Number
  • GRV_FM
    Text
  • EASEMENT
    Text
  • PIPE_STATUS
    Text
  • COMMENTS
    Text
  • WYE_CON
    Number
  • MON_INST
    Text
  • PLAN1
    Text
  • PLAN2
    Text
  • PROF
    Text
  • WYEMAP
    Text
  • HR_VER
    Text
  • PCT_ENTRY
    Text
  • WYE_MAT
    Text
  • WYE_DIAM
    Number
  • WYE_LENG
    Number
  • WYE_UPDATE
    Text
  • EST_UPINV
    Text
  • EST_DNINV
    Text
  • EST_MATL
    Text
  • LINER_DATE
    Text
  • EST_YEAR
    Text
  • EST_YR_LEV
    Text
  • SLOPE2
    Number
  • V_CURVE
    Text
  • PCT_ENTRY2
    Text
  • CAPACITY
    Number
  • SYSTEM
    Text
  • TRTMNT_LOC
    Text
  • OWNER
    Text
  • CRTN_DT
    Date
  • LAST_UPDATE
    Date
  • USER_ID
    Text
  • VDATUM
    Text
  • UP_MH
    Number
  • DN_MH
    Number
  • SAN_PIPE_ID
    Text
  • LAYER
    Number
  • Shape_Length
    Number
  • TOOLTIP
    Text
  • NLA_URL
    Text
  • CLASS_DESC
    Text
  • ENG_DIST_DESC
    Text
  • REHAB_DESC
    Text
  • GRV_FM_DESC
    Text
  • HR_VER_DESC
    Text
  • SYSTEM_DESC
    Text
  • TRTMNT_LOC_DESC
    Text
  • OWNER_DESC
    Text
  • MATERIAL_DESCRIPTION
    Text
  • PIPE_SUBTYPE_DESC
    Text
  • PIPE_STATUS_DESC
    Text